Diaphragm compressor DC 2-20/0.2-200-H2 for hydrogen (H2)

Diaphragm compressor DC 2-20/0.2-200-H2 for hydrogen (H2)

Customer is the factory from aerospace industry.

Delivery date is 2018.06

Description: hydrogen oil-free diaphragm compressor DC 2-20/0.2-200-H2 to compress the high purity hydrogen (H2) (99.99%).

Diapragm compressor DC 2-20/0.2-200-H2 for hydrogen

 

Technical parametres are indicated below:

Model DC 2-20/0.2-200-H2
Compressor type Diaphragm oil-free compressor
Inlet pressure (bar g) 0.2
Outlet pressure (bar g) 200
Inlet gas temperature (°С) -10…+40
Pressure dew point (°С)

gas is dry

Capacity (Nm3/h) 20
Gas H2 (99.9%)
Cooling water
Cooling water temperature (°С) + 1 … + 32
Cooling water capacity (m3/h) 1.5
Cooling water pressure (bar g) ≤ 6
Ambient temperature (°С) + 1 … + 45
Motor power 400/3/50 (kW) 15
Real power consumption (kW) 13.5
Control panel Included as separate unit
Implosion protection (by motor) 1Exd IIC T4
Dimensions LхWхH (мм) 1940х1290х1089
Weight (kg) 1750

 

Compressor description

DC 2-20/0.2-200-H2 is oil-free diaphragm compressor for hydrogen (H2).

It’s 2 stage (2 cylinder) compressor.

Cooling: water. 

More photos are here:

Compressor’s 1st stage

Compressor’s 2nd stage

 

Compressor’s scope of supply

The following was included:

  • 2 stages 2 cylinders compressor block
  • cranck case breather
  • electric motor
  • motor drive pulley
  • v-belts
  • drive guard
  • inlet gas port
  • baseplate with 4 holes
  • manometres (6 pieces are installed on compressor + 6 pieces as spare set)
  • inlet gas pressure sensor
  • outlet gas pressure sensor
  • crank case oil pressure sensor
  • non-return valve for final gas delivery
  • safety valve after the 1st stage and for final gas delivery
  • interstage and final gas cooler
  • two (for 2 stage compressor) pressure relays to control the diaphragm rapture
  • tubes “inside” compressor
  • terminal box
  • electrical connections to terminal box “inside” compressor
  • control panel as separate unit for installation in the safe area
  • additional control device with Start/Stop/Emergency stop buttons + Green/Red/Yellow lamps for installation with compressor in explosive zone
  • water cooling
  • manual oil pressure setting in compressor  

Compressor was delivered as totally accembled unit, tested and ready for the comissioning.

Control panel

Compressor was equipped with control panel for hasardous area installation.

Control panel for H2 diaphragm compressor

This is inside:

Inside the control panel for H2 diaphragm compressor

Additional control device with Start/Stop/Emergency stop buttons + Green/Red/Blue lamps for installation with compressor in explosive zone is always included.

Control Start/Stop device

Gauge panel

Gauge panel is placed on the front side of compressor.

Gauge panel for H2 diapragm compressor

15 kW motor is installed.

15 kW motor

Pressure relays to control the diaphragm rapture:

Pressure relays to control the diaphragm rapture

Terminal box

Terminal box

1st stage safety valve

1st stage safety valve

2nd stage valve

2nd stage safety valve

The place of safety valves installation

The place of safety valves installation

Cooler

Cooler

Cooler

Baseplate with 4 holes

Baseplate with 4 holes

Compressor during tests

Compressor during tests

 

That’s all.

If you need any help with compressors for hydrogen (H2) please don’t hesitate to contact us.

You can send request and will answer during the one working day.

 

Best regards,

Konstantin Shirokikh

 

Add comment

Your email address will not be published. Required fields are marked *